Use of cable

as fieldbus cables for CAN (Controller Area Network) systems, in the field of factory automation, for fixed installation & flexible applications.

This bussystem has its origins in the automotive sector and has established itself in the field of production automation.
Standard acc. to CAN Spec.: ISO 11898

Special features

  • largely resistant to grease, coolant fluids and lubricants
  • oil-resistant: acc. to DIN EN 60811-2-1 (only mineral oil))
  • UV-resistant (TRAY & BURIAL)
  • direct burial (BURIAL)
  • EMC compliant shielding
  • max. transmission rate: 1 Mbit/s at 40m segment length
  • max. cable lengths for a bus segment depending on the cross section
                0- 40 m AWG24, AWG22 | 40-300 m AWG22, AWG20 |
                300-600 m AWG20 | 600-1.000 m AWG19

Remarks

  • conform to RoHS
  • conform to DESINA (violet)
  • conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
  • LABS-/silicone-free (during production)
Conductor material: Copper conductor blank
Conductor class: 0,22, 0,34 & 0,5mm²: 7-wired; fine wired acc. to IEC 60228 cl. 5
Core insulation: Foamed PE/PP
Core identification: Acc. to DIN VDE 47100
Stranding: Cores twisted to pairs, TRAY-version: star quad
Inner sheath material: TRAY: PVC
Shield3: Copper braid tinned
Outer sheath: PVC resp. BURIAL: PVC/PE
Sheath colour: Violet RAL 4001 (VT) or black (BK)
Rated voltage: 250 V (not for high voltage purposes)
Testing voltage: 1,5 kV
Loop resistance: Max. 175,2 Ω/km - AWG 24, max. 110,8 Ω/km - AWG 22; max. 68,8 Ω/km - AWG 20; max 55,0 Ω/km - AWG 19
Capacity: Nom. 40 nF/km
Characteristic impedance: 120 Ω +/- 12 Ω
Min. bending radius fixed: 7,5 x d
Min. bending radius moved: 15 x d
Operat. temp. fixed min/max: -40 °C / +80 °C
Operat. temp. moved min/max: -10 °C / +70 °C
Burning behavior: PE: not flame retardant | PVC CMX: flame retardant acc. to IEC 60332-1-2, VW-1 | TRAY: acc. to IEC 60332-3-24 (Cat.C), FT4
Resistant to oil: Acc. to DIN EN 60811-2-1 (only mineral oil)
Approvals: UL/CSA - cULus 300V, 75°C, CMX | TRAY: cULus 300V, 75°C, CMG/PLTC-ER/SunRes/OilRes

Table of items

Product No.
Dimension
[n x mm²]
Outer-Ø
[mm]
Cu-Index
[kg/km]
Weight
[kg/1.000]
Sheath colour
Variant
2003675 1 X 2 X AWG 24/7 (0,22 mm²) 5,7 19,0 40,0 violet V1: CAN BUS C-PVC UL/CSA - cULus - CMX DESINA
2003676 2 X 2 X AWG 24/7 (0,22 mm²) 7,4 38,0 60,0 violet V1: CAN BUS C-PVC UL/CSA - cULus - CMX DESINA
2003677 1 X 2 X AWG 22/7 (0,34 mm²) 6,7 28,0 56,0 violet V1: CAN BUS C-PVC UL/CSA - cULus - CMX DESINA
2003678 2 X 2 X AWG 22/7 (0,34 mm²) 8,5 48,0 85,0 violet V1: CAN BUS C-PVC UL/CSA - cULus - CMX DESINA
2003679 1 X 2 X AWG 20/7 (0,5 mm²) 7,5 44,0 73,0 violet V1: CAN BUS C-PVC UL/CSA - cULus - CMX DESINA
2003680 2 X 2 X AWG 20/7 (0,5 mm²) 9,6 61,0 107,0 violet V1: CAN BUS C-PVC UL/CSA - cULus - CMX DESINA
2003681 1 X 2 X AWG 19 (0,75 mm²) 8,7 56,0 93,0 violet V1: CAN BUS C-PVC UL/CSA - cULus - CMX DESINA
2003682 2 X 2 X AWG 19 (0,75 mm²) 11,6 84,0 157,0 violet V1: CAN BUS C-PVC UL/CSA - cULus - CMX DESINA
2003683 2 X 2 X AWG 22/7 (0,34 mm²) 7,5 48,0 81,0 violet V2: CAN BUS TRAY C-PVC UL/CSA - cULus - CMG|PLTC DESINA
2003684 2 X 2 X AWG 20/7 (0,5 mm²) 9,6 61,0 99,0 violet V2: CAN BUS TRAY C-PVC UL/CSA - cULus - CMG|PLTC DESINA
2003685 2 X 2 X AWG 20/7 (0,5 mm²) 11,6 61,0 138,0 black V3: CAN BUS BURIAL C-PVC/PE
2003686 2 X 2 X AWG 19 (0,75 mm²) 13,6 84,0 194,0 black V3: CAN BUS BURIAL C-PVC/PE