Use of cable

as fieldbus cables for CAN (Controller Area Network) systems, in the field of factory automation, for high flexible applications (e.g. power chains, gantry robots, pick&place units, conveyors, machine tools, automated production systems, etc.)

This bussystem has its origins in the automotive sector and has established itself in the field of production automation. 
Standard acc. to CAN Spec.: ISO 11898

Special features

  • low adhesion
  • largely resistant to grease, coolant fluids and lubricants
  • oil-resistant: acc. to DIN EN 60811-2-1
  • UV-resistant
  • EMC compliant shielding
  • max. transmission rate: 1 Mbit/s at 40m segment length 
  • max. cable lengths for a bus segment depending on the cross section
               0- 40 m AWG24, AWG22 |  40-300 m AWG22, AWG20 |
               300-600 m AWG20 |  600-1.000 m AWG19

Remarks

  • conform to RoHS
  • conform to DESINA (violet)
  • conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE
  • LABS-/silicone-free (during production)
  • FRNC: Flame Retardant Non Corrosive, halogen free
Conductor material: Copper conductor blank
Conductor class: Super fine wire acc. to IEC 60228 cl. 6
Core insulation: Foamed PE/PP
Core identification: Acc. to DIN 47100
Stranding: Cores twisted to pairs
Shield3: Copper braid tinned
Outer sheath: PUR
Sheath colour: Violet RAL 4001 (VT)
Rated voltage: 250 V (not for high voltage purposes)
Testing voltage: 1,5 kV
Loop resistance: Max. 175,2 Ω/km - AWG 24, max. 110,8 Ω/km - AWG 22; max. 68,8 Ω/km - AWG 20; max 55,0 Ω/km - AWG 19
Capacity: Nom. 40 nF/km
Characteristic impedance: 120 Ω +/- 12 Ω
Min. bending radius fixed: 5 x d
Min. bending radius moved: 7,5 x d < 3mTL* | 15 x d ≥ 3mTL*
Operat. temp. fixed min/max: -40 °C / +80 °C
Operat. temp. moved min/max: -30°C / +70°C
Halogen free: Acc. to IEC 60754-1 (FRNC Typen)
Burning behavior: Flame-retardant acc. to IEC 60332-1-2, VW-1
Resistant to oil: Acc. to DIN EN 60811-2-1
Approvals: UL/CSA - cULus 300V, 75°C, CMX
Speed: Self-supporting: 4 m/s
Acceleration: Max. 5 m/s²

Table of items

Product No.
Dimension
[n x mm²]
Outer-Ø
[mm]
Cu-Index
[kg/km]
Weight
[kg/1.000]
Sheath colour
Variant
2003674 1 X 2 X AWG 24 (0,25 mm²) 6,5 25,0 53,0 violet V1: CAN BUS SK-C-PUR FRNC UL/CSA - cULus - CMX DESINA
2003687 2 X 2 X AWG 24 (0,25 mm²) 8,4 43,0 77,0 violet V1: CAN BUS SK-C-PUR FRNC UL/CSA - cULus - CMX DESINA
2003688 1 X 2 X AWG 22 (0,34 mm²) 6,9 34,0 52,0 violet V2: CAN BUS SK-C-PUR FRNC UL/CSA - cULus - CMX DESINA2
2003689 2 X 2 X AWG 22 (0,34 mm²) 9,5 54,0 95,0 violet V2: CAN BUS SK-C-PUR FRNC UL/CSA - cULus - CMX DESINA2
2003690 1 X 2 X AWG 20 (0,53 mm²) 8,0 43,0 72,0 violet V2: CAN BUS SK-C-PUR FRNC UL/CSA - cULus - CMX DESINA2
2003691 2 X 2 X AWG 20 (0,53 mm²) 10,2 60,0 98,0 violet V2: CAN BUS SK-C-PUR FRNC UL/CSA - cULus - CMX DESINA2